OPERATING INSTRUCTIONS
Model PD100 POSITION DETECTOR
DESCRIPTION
The Model PD100 Position Detector comprises a control module in a sheet metal housing and a
single remote probe, forming a system that detects the proximity of a metal target to the face of
the probe. The positioning threshold is established by positioning the moving members to the
point of maximum allowed separation and pressing the calibration push button on the front panel
of the PD100. Whenever the probe and target are separated by more than the calibrated distance,
the output relay switches to indicate the condition.
January 27, 1999
OK OUT
CALIBRATE
Model PD100
Metal Target
Position Detector
P
RIME
CONTROLS, INC.
AC
AC
RELAY
POWER
OUTPUT
RESET
COM
METAL
WHITE
RED
CAL
BLACK
SHLD
PROBE
CONTROL
SET JUMPERS
(120V OR 240V)
POSITION
Vue de la page 0
1 2 3 4 5 6 7 8 9 10

Résumé du contenu

Page 1 - Model PD100

OPERATING INSTRUCTIONSModel PD100 POSITION DETECTORDESCRIPTIONThe Model PD100 Position Detector comprises a control module in a sheet metal housing an

Page 2

10LIMITATION AND EXCLUSION OF WARRANTIESAll goods purchased from Prime Controls, Inc. shall be free from defects in materials, design and workmanshipu

Page 3

2Control ModuleThe control module allows fast and easy setup and for diagnosis of system errors or problems.Calibration is achieved through the simple

Page 4

3Probe Model Probe Diameter Min Cal Distance Max Cal DistancePM4 18 mm (0.070”) 0 mm (0”) 0.6 mm (0.024”)PM10 30 mm (1.18”) 0 mm (0”) 1.5 mm (0.060”

Page 5

43. Connections to the control circuit of the machine are made through the form C output relay.This relay is powered in the OK condition. The relay p

Page 6 - PM15 Backoff Distance

5A two position DIP switch between the two main connectors, is visible from the connector edgeof the unit. These switches are for future expansion an

Page 7

6CONFIGURATION SWITCHES AND JUMPERSA two position switch is located on the main control circuit board in the opening between thetwo connectors. These

Page 8

7FIRMWARE VERSIONFrom time to time, as improvements are made to Prime products, the firmware controlling theunits is revised. When setting a unit up

Page 9

8TROUBLESHOOTINGShould trouble develop, proceed as follows:1. Check AC input power to the control module 2. Check the fuse, accessible at the lower

Page 10

9(6.50)(5.875)OK OUTCALIBRATEModel PD100Metal TargetPosition DetectorPRIMECONTROLS, INC.ACACRELAYPOWEROUTPUT(1.32)(0.600)15.233.5165.1149.27.9(0.31)(