Probe Model Probe Diameter Min Cal Distance Max Cal Distance
PM4 18 mm (0.070”) 0 mm (0”) 0.6 mm (0.024”)
PM10 30 mm (1.18”) 0 mm (0”) 1.5 mm (0.060”)
PM15 36 mm (1.42”) 0 mm (0”) 2.0 mm (0.080”)
INSTALLATION
Installation of the individual components of the Position Detector system is covered in the
following paragraphs:
PD100 Control Module
The control board is designed to mount on the back panel of an electrical enclosure using the four
mounting slots at the edges of the enclosure. The footprint is 6.5 inches (165 mm) by 6.25 inches
(159 mm) with mounting slot locations on a rectangle 5.875 inches (149 mm) in the horizontal
and 4.0 inches (102 mm) in the vertical (see drawing at end of this document). Insure that the
mounting screws make good electrical contact between the module housing and a well grounded
control enclosure back panel.
Avoid mounting locations with excessive heat and vibration.
Probes
The probe must be mounted so that the nearest position of the target is either in contact with the
probe or as far away as indicated in the chart found earlier in this document. We recommend
maintaining a small separation between the probe and target to minimize shock and prolong the
life of the probe.
Electrical Wiring
All wiring for the PD100 connects to removable terminal blocks at the bottom of the control
enclosure as described in the following paragraphs.
1. Connect l00 to l30 VAC (50-6O Hz. @15watts) to the terminals labeled AC on the left of
terminal block. Connect earth ground to the leftmost terminal.
2. For 200 to 260 volt operation remove the PD100 cover and remove suitcase jumpers A and
C immediately in front of the gray transformer block. Place one of the suitcase jumpers in
position B. Discard the second jumper. Replace the cover. The factory setting for these
jumpers is for 100 to 130 volt operation. Do not power the Model PD100 with 200 to 260
VAC until jumpers have been changed.